PRODUCTS
- Distribution Transformer
- Resin Casting Dry Type Power Transformer
- Whole-sealed Type Distribution Power Transformer
- Electrical Power Fitting
- Power Transmission and Distribution Fittings
- Power Line Fittings
- Power Line Helical Fittings
- High Voltage Outdoor Electrical Equipment
- Copper and Aluminum Contact Arms
- Lightening Protection Grounding Clamps
- Electric Wire & Cable and Accessories
- Rubber Sheathed Cable for General Purposes
- Rubber Insulated Cables Used in Open Countr
- Flame-retardant Rubber Sheathed Cables for Mining Purposes
- PVC Insulated Cable for House Wiring
- XLPE Insulated Power Cable
- PVC Insulated Power Cable
- Low-smoke Halogen-free Flame-retardant and Fire-resistant Cables
- Control Cables
- Overhead Conductors and Cables
- Aluminum wire and ACSR
- Special Cables
- Elevator Cable
HOTLINE
0577-57157777
Overhead Conductors and Cables
Overhead Insulated Cables of Rated Voltage 10kV and below
- Share:
1. Standard
GB/T 14049, IEC 60502
2. Application
This product is mainly used in overhead power transmission lines of rated voltage 10kV and below.
3. Code and Description
JKYJ: copper conductor XLPE insulated overhead cable
JKLYJ: aluminium conductor XLPE insulated overhead cable;
JKY: copper conductor PE insulated overhead cable;
JKLY: aluminium-conductor XLPE insulated overhead cable;
JKLYJ/Q: light duty aluminium conductor XLPE insulated overhead cable;
JKLY/Q: light duty aluminium conductor PE insulated overhead cable.
4. Model
1 Core: 16~300mm2
5. Guide to Use
1) It is suitable for overhead transmission lines of AC system. When used in DC system, the system rated voltage shall be less than 1.5 times rated voltage of the cable.
2) Ambient temperature of the cable shall be -20~50℃.
3) The min. bend radius of the cable is 20 x (D + d), where D is the diameter of the cable and d the diameter of the conductor.
6. Technical Particulars
JKYJ: copper conductor XLPE insulated overhead cable
JKLYJ: aluminium conductor XLPE insulated overhead cable;
JKY: copper conductor PE insulated overhead cable;
JKLY: aluminium-conductor XLPE insulated overhead cable;
JKLYJ/Q: light duty aluminium conductor XLPE insulated overhead cable;
JKLY/Q: light duty aluminium conductor PE insulated overhead cable.
4. Model
1 Core: 16~300mm2
5. Guide to Use
1) It is suitable for overhead transmission lines of AC system. When used in DC system, the system rated voltage shall be less than 1.5 times rated voltage of the cable.
2) Ambient temperature of the cable shall be -20~50℃.
3) The min. bend radius of the cable is 20 x (D + d), where D is the diameter of the cable and d the diameter of the conductor.
6. Technical Particulars
Sectional Area | Min. Strands of Conductor | Conductor Diameter | Min. Conductor Screen Thickness | Insulation Nominal Thickness | Max. Conductor DC Resistence at 20℃ (Ω/km) | Min. Tensile Strength (N) | ||||||
mm2 | mm | 10KV | Thin-type | Normal-type | Hard Copper | Soft Copper | Aluminum | Al-alloy | Hard Copper | Aluminum | Al -alloy | |
10 | 6 | 3.8 | 0.5 | 3.4 | 1.830 | 3.080 | ||||||
16 | 6 | 4.8 | 0.5 | 3.4 | 1.150 | 1.190 | ||||||
25 | 6 | 6.0 | 0.5 | 2.5 | 3.4 | 0.749 | 0.727 | 1.200 | 1.393 | 8465 | 3762 | 6284 |
35 | 6 | 7.0 | 0.5 | 2.5 | 3.4 | 0.540 | 0.524 | 0.868 | 1.007 | 11731 | 5177 | 8800 |
50 | 6 | 8.4 | 0.5 | 2.5 | 3.4 | 0.399 | 0.387 | 0.641 | 0.744 | 16502 | 7011 | 12569 |
70 | 12 | 10.0 | 0.5 | 2.5 | 3.4 | 0.276 | 0.268 | 0.443 | 0.514 | 23461 | 10354 | 17596 |
95 | 15 | 11.6 | 0.6 | 2.5 | 3.4 | 0.199 | 0.193 | 0.320 | 0.371 | 31759 | 13727 | 23880 |
120 | 18 | 13.0 | 0.6 | 2.5 | 3.4 | 0.158 | 0.153 | 0.253 | 0.294 | 39911 | 17339 | 30164 |
150 | 18 | 14.6 | 0.6 | 2.5 | 3.4 | 0.128 | 0.206 | 0.239 | 49505 | 21033 | 37706 | |
185 | 30 | 16.2 | 0.6 | 2.5 | 3.4 | 0.1021 | 0.164 | 0.190 | 61846 | 26732 | 46503 | |
240 | 34 | 18.4 | 0.6 | 2.5 | 3.4 | 0.0777 |
|
0.125 | 0.145 | |||
300 | 34 | 20.6 | 0.6 | 2.5 | 3.4 | 0.0619 |
|
0.100 | 0.100 | 79823 | 34679 | 60329 |