Flame-retardant Rubber Sheathed Cables for Mining Purposes

Flexible Coal Cutter Cables with Individual Metallic Screens of Rated Voltage up to 1.9/3.3kV

Flexible Coal Cutter Cables with Individual Metallic Screens of Rated Voltage up to 1.9/3.3kV

    Share:

1. Application

This product is used as power supply connection cable for coal cutters or similar equipment of rated voltage 1.9/3.3kV and below.


2. Guide to Use

The max. conductor temperature in normal use is 90℃ and the min. bend radius of the cables is 6 times cable diameter.

3. Code, Description and Usage
Code Description Usage
MCPT-1.9/3.3 1.9/3.3kV flexible coal cutter cable with individual metallic screen Power supply connection cable for 1.9/3.3kV coal cutters and similar equipment
MCPTJ1.9/3.3 1.9/3.3kV flexible coal cutter cable with individual metallic screen and monitoring core Power supply connection cable for 1.9/3.3kV coal cutters and similar equipment
MCPTJ-0.66/1.14 0.66/1.14kV flexible coal cutter cable with individual metallic screen and monitoring core Power supply connection cable for 0.66/1.14kV coal cutters and similar equipment

4. Sectional Drawing


5. Technical Parameters

1) MCPT-0.66/1.14, MCPTJ-0.66/1.14

No. of Cores * Sectional Area
(mm2)
Nominal Thickness (mm) Overall Diameter (mm)
Power Core Ground Core Control Core Auxiliary Core Power Core Insulation (mm) Sheath (mm) MCPT-0.66/1.14 MCPTJ-0.66/1.14
3*25 1*16 3*4 1*16 1.6 5.0 39.7-42.9 39.7-42.9
3*35 1*16 3*4 1*16 1.6 5.0 43.1-46.3 43.4-46.3
3*50 1*25 3*4 1*25 1.7 5.3 48.5-51.8 48.5-51.8
3*70 1*35 3*6 1*35 1.8 5.8 55.1-58.8 15.1-58.8
3*95 1*50 3*6 1*50 2.0 6.4 62.4-66.1 62.4-66.1
3*120 1*50 3*10 1*70 2.2 6.9 68.0-72.5 68.0-72.5
3*150 1*70 3*10 1*70 2.4 7.3 74.5-79.5 74.5-79.5

Note: the outer diameter of monitoring core shall be the same as that of the power core


2) MCPJB-0.66/1.14

No. of Cores * Sectional Area
(mm2)
Nominal Thickness (mm) Overall Diameter (mm)
Power Core Ground Core Control Core Power Core Insulation (mm) Sheath (mm) MCPJB-0.66/1.14
3*25 1*16 1*16 1.6 5.1 47.4-49.9
3*35 1*16 1*16 1.6 5.5 51.6-54.6
3*50 1*25 1*25 1.7 5.9 56.8-59.8
3*70 1*35 1*35 1.8 6.4 62.8-67.8
3*95 1*50 1*50 2.0 6.9 68.9-72.7
3*120 1*50 1*70 2.2 7.3 73.4-77.2
3*130 1*70 1*70 2.4 7.8 79.0-83.6

Note: the outer diameter of monitoring core shall be the same as that of the power core


3) MCPJB-0.66/1.14

No. of Cores * Sectional Area
(mm2)
Nominal Thickness (mm2) Overall Diameter (mm)
Power Core Ground Core Control Core Power Core Insulation (mm) Sheath (mm) MCPJB-0.66/1.14
3*25 1*16 3*4 3.0 5.1 47.4-49.9
3*35 1*16 3*4 3.0 5.5 51.6-54.6
3*50 1*25 3*4 3.0 5.9 56.8-59.8
3*70 1*35 3*6 3.0 6.4 62.8-67.8
3*95 1*50 3*6 3.0 6.9 68.9-72.7
3*120 1*50 3*10 3.0 7.3 73.4-77.2
3*130 1*70 3*10 3.0 7.8 79.0-83.6
Note: the outer diameter of monitoring core shall be the same as that of the power core

6. Technical Performance
1) The conductor resistance meets the following requirements
Power Core Sectional Area (mm2) Conductor DC resistance at 20℃ (Ω/kM) Power Core Sectional Area (mm2) Conductor DC resistance at 20℃ (Ω/kM)
16 ≤1.24 50 ≤0.393
25 ≤0.795 70 ≤0.277
35 ≤0.565 95 ≤0.210
120 ≤0.164 150 ≤0.132

2) The insulation resistance meets the following requirements
Power Core Sectional Area (mm2) Insulation Resistance at 20℃ (MΩ·kM)
0.66/1.15 KV
1.9/3.3 KV
16 ≥350
-
26 ≥350 -
35 ≥300 ≥400
50 ≥250 ≥350
70 ≥250 ≥300
95 ≥200 ≥250
120 ≥200 ≥250
150 ≥180 ≥250
Control Core 4/6/10 ≥100 ≥100

3) Max. conductor temperature in normal use: 90℃.
4) Insulation tensile strength is over 6.5MPa, and has an elongation of over 200% at break.
5) Sheath tensile strength is over 11.0MPa, and has an elongation of over 250% at break.
6) 0.38/0.66kV cables can withstand a 3.0kV/5Min voltage test and no breakdown shall occur; 0.66/1.14kV cables can withstand a 3.7kV/5Min voltage test and no breakdown shall occur.
7) The flame-retardant performance of the cable meets all requirements of burn test in standard MT 386-1995.

Other Products

  • Flexible Rubber Sheathed Coal Cutter Cables for Rated Voltage up to 1.9/3.3kV

  • 0.66/1.14kV Screened Coal Cutter Cable with Reinforced Layer and Monitoring Core

  • Flexible Frequency Converter Cable for Coalcutter of Rated Voltage 8.7/10kV and below

  • Flexible Rubber-sheathed Portable Mining Cables for Rated Voltage up to 0.66/1.14kV

  • Rubber Sheathed Flexible Cable with Metallic Screen and Monitoring Core of Rated Voltage 8.7/10kV and below

  • Rubber-sheathed Flexible Portable Cables of Rated Voltage up to 6/10kV

  • Drill Cable for Mining Use of Rated Voltage 0.3/0.5KV

  • 0.3/0.5kV Light-duty Flexible Portable Cable for Mining Use

  • 0.6/1kV PVC Insulated Power Cable for Mining Use